SP.-EA-DA-x-145AE7-B23 C
5.21 kW
Defrost: Electric
Product code: EA-DA-x-235BE7-B21 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 4,080 m³/h |
|---|---|
| Air throw | 12 m |
| External surface | 25.3 m² |
| Inner volume | 9.5 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 75 kg |
| Quantity | 2 |
|---|---|
| Diameter | 350 mm |
| Speed | 1,340 rpm |
| Power | 330 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 51.0 dB(A) |
|---|---|
| Sound power | 73.0 dB(A) |
| Energy class | D |
| Inlet | Ø12,7 |
|---|---|
| Outlet | Ø15,9 |
| EA-DA-x-235BE7-B21 C | None |
|---|---|
| EA-DA-x-235BE7-B21 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | not rated | 2.05 | 2.27 | 2.47 | 2.62 | 2.72 | 2.77 | 2.88 | 3.09 | 3.38 | 3.31 | 3.30 | 3.27 | 3.24 |
| 5 | not rated | not rated | 2.83 | 3.11 | 3.29 | 3.45 | 3.56 | 3.70 | 3.96 | 4.35 | 4.30 | 4.27 | 4.23 | 4.16 |
| 6 | not rated | not rated | 3.05 | ≈ 3.59 | 3.89 | 4.12 | 4.29 | 4.46 | 4.78 | 5.25 | 5.20 | 5.17 | 5.12 | 5.01 |
| 7 | not rated | not rated | not rated | 4.05 | 4.44 | 4.75 | 4.98 | 5.20 | 5.58 | 6.14 | 6.09 | 6.06 | 6.00 | 5.87 |
| 8 | 1.27 | ≈ 1.25 | ≈ 1.94 | ≈ 4.48 | 4.95 | 5.35 | 5.65 | 5.92 | 6.36 | 7.02 | 6.99 | 6.95 | 6.88 | 6.73 |
| 9 | 1.40 | 1.38 | not rated | ≈ 4.20 | ≈ 5.42 | 5.90 | 6.28 | 6.62 | 7.12 | 7.87 | 7.86 | 7.83 | 7.76 | 7.59 |
| 10 | 1.53 | 1.51 | ≈ 1.51 | ≈ 2.30 | ≈ 5.85 | 6.42 | 6.88 | 7.29 | 7.86 | 8.70 | 8.72 | 8.69 | 8.63 | 8.46 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 8.723 |
| SC2 | 0 | 8 | 5.922 |
| SC3 | -18 | 7 | 4.217 |
| SC4 | -25 | 6 | 3.046 |
| SC5 | -34 | 6 | — |
| A | 1457 mm |
|---|---|
| B | 730 mm |
| C | 530 mm |
| F | 560 mm |
| E1 | 518 mm |
| E | 1035 mm |
| D IN | 1 x Ø12,7 |
| D OUT | 1 x Ø15,9 |
| Length | 1457 mm |
|---|---|
| Width | 730 mm |
| Height | 530 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.