Skip to Content

EB (General)

Application
Cubic, Commercial
Air discharge
Single
Refrigerants
R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a, R744
Capacity
0.64–32.06 kW
Fans
⌀200, ⌀250, ⌀300, ⌀350, ⌀400, ⌀450 mm
Max. working pressure
25 bar
EB (General)

Model nomenclature

How to read the model codes of this series, with an example.

  • A
    Model code (series) EB = EB - economical unit cooler
  • B
    Number of fans — Number of fans (one digit).
  • C
    Fan diameter — Fan diameter in cm (two digits; x10 = mm), e.g. 30=Ø300, 63=Ø630, 91=Ø910. 20 = Ø200 mm25 = Ø250 mm30 = Ø300 mm35 = Ø350 mm40 = Ø400 mm45 = Ø450 mm
  • D
    Dimensional data - coil size letter — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
  • E
    Dimensional data - tube rows — Second letter of the dimensional data = number of tube rows (coil depth): A=2, B=3, C=4, D=5, E=6, G=8, I=10, K=12 (alphabet position + 1). A = 2 tube rowsB = 3 tube rowsC = 4 tube rowsE = 6 tube rows
  • F
    Fin spacing — Nominal fin spacing in mm (1-2 digits). Karyer catalogue: 4=4.20, 6=6.00. The exact pitch is per model (e.g. 4 covers 3.8 to 4.6 mm). 4 = Fin spacing about 4 mm6 = Fin spacing about 6 mm7 = Fin spacing about 7 mm
  • G
    Generation code — Karyer design generation letter; Karyer publishes no further decoding. B = Generation BC = Generation C
  • H
    Fan data 01 = Ø300: 230V/1Ph/50Hz, 4-pole; Ø350: 230V/1Ph/50Hz, 4-pole; Ø400: 230V/1Ph/50Hz, 4-pole; Ø450: 230V/1Ph/50Hz, 4-pole05 = Ø200: 230V/1Ph/50Hz, 4-pole; Ø250: 230V/1Ph/50Hz, 4-pole; Ø300: 230V/1Ph/50Hz, 4-pole07 = Ø450: 400V/3Ph/50Hz, 4-pole
  • J
    Option suffix (variant) — Optional, on BRI variant codes only: " ED" = electric defrost variant; no suffix = standard variant. ED = Electric defrost
Model Cooling capacity [kW] i Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 % Fin spacing [mm] Fans Air throw [m] Air flow [m³/h] Defrost Variants
EB-325BC6-B05 C 4.80 kW 6.0 3 × ⌀250 6 2,556 None, Electric
Variants (2)
EB-325AC4-B05 C 4.85 kW 4.2 3 × ⌀250 5 2,324 None, Electric
Variants (2)
EB-140AC6-B01 C 4.89 kW 6.0 1 × ⌀400 12 3,459 None, Electric
Variants (2)
EB-425BB7-B05 C 4.94 kW 7.0 4 × ⌀250 6 3,585 None, Electric
Variants (2)
EB-330AB6-B01 C 4.94 kW 6.0 3 × ⌀300 8 4,167 None, Electric
Variants (2)
EB-230AE7-B01 C 4.97 kW 7.0 2 × ⌀300 7 2,373 None, Electric
Variants (2)
EB-135AE6-B01 C 5.02 kW 6.0 1 × ⌀350 11 2,465 None, Electric
Variants (2)
EB-230BC4-B01 C 5.08 kW 4.2 2 × ⌀300 7 2,664 None, Electric
Variants (2)
EB-230BE7-B05 C 5.10 kW 7.0 2 × ⌀300 6 2,258 None, Electric
Variants (2)
EB-330BB7-B01 C 5.11 kW 7.0 3 × ⌀300 8 4,443 None, Electric
Variants (2)
EB-330BB6-B05 C 5.19 kW 6.0 3 × ⌀300 8 3,954 None, Electric
Variants (2)
EB-230AE6-B01 C 5.20 kW 6.0 2 × ⌀300 7 2,322 None, Electric
Variants (2)
EB-330AC7-B05 C 5.22 kW 7.0 3 × ⌀300 7 3,505 None, Electric
Variants (2)
EB-230AE4-B01 C 5.25 kW 4.2 2 × ⌀300 6 2,192 None, Electric
Variants (2)
EB-425BB6-B05 C 5.29 kW 6.0 4 × ⌀250 6 3,554 None, Electric
Variants (2)
EB-425AC7-B05 C 5.30 kW 7.0 4 × ⌀250 6 3,283 None, Electric
Variants (2)
EB-230BE6-B05 C 5.34 kW 6.0 2 × ⌀300 6 2,204 None, Electric
Variants (2)
EB-330AB4-B05 C 5.34 kW 4.2 3 × ⌀300 7 3,548 None, Electric
Variants (2)
EB-230BE4-B05 C 5.39 kW 4.2 2 × ⌀300 6 2,067 None, Electric
Variants (2)
EB-145AC7-B01 C 5.46 kW 7.0 1 × ⌀450 16 5,203 None, Electric
Variants (2)
EB-325BC4-B05 C 5.51 kW 4.2 3 × ⌀250 6 2,479 None, Electric
Variants (2)
EB-145AC7-B07 C 5.52 kW 7.0 1 × ⌀450 16 5,408 None, Electric
Variants (2)
EB-330BB6-B01 C 5.56 kW 6.0 3 × ⌀300 8 4,393 None, Electric
Variants (2)
EB-330AC6-B05 C 5.56 kW 6.0 3 × ⌀300 7 3,433 None, Electric
Variants (2)
EB-230BE7-B01 C 5.59 kW 7.0 2 × ⌀300 7 2,561 None, Electric
Variants (2)
EB-425AB4-B05 C 5.60 kW 4.2 4 × ⌀250 6 3,305 None, Electric
Variants (2)
EB-135AE4-B01 C 5.64 kW 4.2 1 × ⌀350 10 2,339 None, Electric
Variants (2)
EB-330AC7-B01 C 5.64 kW 7.0 3 × ⌀300 8 3,955 None, Electric
Variants (2)
EB-140AC4-B01 C 5.67 kW 4.2 1 × ⌀400 12 3,342 None, Electric
Variants (2)
EB-425AC6-B05 C 5.70 kW 6.0 4 × ⌀250 6 3,239 None, Electric
Variants (2)
EB-330AB4-B01 C 5.79 kW 4.2 3 × ⌀300 8 3,998 None, Electric
Variants (2)
EB-145AC6-B01 C 5.80 kW 6.0 1 × ⌀450 16 5,111 None, Electric
Variants (2)
EB-140AE7-B01 C 5.84 kW 7.0 1 × ⌀400 12 3,233 None, Electric
Variants (2)
EB-230BE6-B01 C 5.87 kW 6.0 2 × ⌀300 7 2,517 None, Electric
Variants (2)
EB-430AB7-B05 C 5.90 kW 7.0 4 × ⌀300 8 5,044 None, Electric
Variants (2)
EB-330BC7-B05 C 5.90 kW 7.0 3 × ⌀300 7 3,785 None, Electric
Variants (2)
EB-230BE4-B01 C 5.96 kW 4.2 2 × ⌀300 7 2,402 None, Electric
Variants (2)
EB-330AC6-B01 C 5.97 kW 6.0 3 × ⌀300 8 3,886 None, Electric
Variants (2)
EB-425BC7-B05 C 6.02 kW 7.0 4 × ⌀250 6 3,446 None, Electric
Variants (2)
EB-425BB4-B05 C 6.10 kW 4.2 4 × ⌀250 6 3,466 None, Electric
Variants (2)
EB-430AB7-B01 C 6.16 kW 7.0 4 × ⌀300 8 5,633 None, Electric
Variants (2)
EB-330BB4-B05 C 6.16 kW 4.2 3 × ⌀300 7 3,821 None, Electric
Variants (2)
EB-140AE6-B01 C 6.23 kW 6.0 1 × ⌀400 11 3,181 None, Electric
Variants (2)
EB-430AB6-B05 C 6.28 kW 6.0 4 × ⌀300 7 4,957 None, Electric
Variants (2)
EB-330BC6-B05 C 6.33 kW 6.0 3 × ⌀300 7 3,719 None, Electric
Variants (2)
EB-330AC4-B05 C 6.33 kW 4.2 3 × ⌀300 6 3,234 None, Electric
Variants (2)
EB-330BC7-B01 C 6.33 kW 7.0 3 × ⌀300 8 4,226 None, Electric
Variants (2)
EB-425BC6-B05 C 6.40 kW 6.0 4 × ⌀250 6 3,408 None, Electric
Variants (2)
EB-430BB7-B05 C 6.40 kW 7.0 4 × ⌀300 8 5,335 None, Electric
Variants (2)
EB-425AC4-B05 C 6.44 kW 4.2 4 × ⌀250 6 3,100 None, Electric
Variants (2)

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.