EA-235AG7-C01 C
9.24 kW
Defrost: None
Product code: EA-240AC6-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 6,360 m³/h |
|---|---|
| Air throw | 13 m |
| External surface | 28.1 m² |
| Inner volume | 8.5 dm³ |
| Fin spacing | 6.0 mm |
| Fin material | Aluminium |
| Net weight | 59 kg |
| Quantity | 2 |
|---|---|
| Diameter | 400 mm |
| Speed | 1,430 rpm |
| Power | 320 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 61.0 dB(A) |
|---|---|
| Sound power | 83.0 dB(A) |
| Energy class | C |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø28 |
| EA-240AC6-C01 C | None |
|---|---|
| EA-240AC6-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3.34 | 3.39 | 3.43 | 3.47 | 3.48 | 3.46 | 3.43 | 3.49 | 3.70 | 3.99 | 3.89 | 3.85 | 3.80 | 3.72 |
| 5 | 4.38 | 4.52 | 4.63 | 4.75 | 4.80 | 4.81 | 4.79 | 4.85 | 5.16 | 5.58 | 5.44 | 5.39 | 5.32 | 5.22 |
| 6 | 5.32 | 5.58 | 5.82 | 6.03 | 6.17 | 6.24 | 6.25 | 6.31 | 6.70 | 7.26 | 7.08 | 7.01 | 6.90 | 6.74 |
| 7 | 6.11 | 6.48 | 6.82 | 7.08 | 7.29 | 7.43 | 7.51 | 7.64 | 8.12 | 8.84 | 8.67 | 8.60 | 8.49 | 8.32 |
| 8 | 6.83 | 7.27 | 7.72 | 8.13 | 8.42 | 8.62 | 8.74 | 8.90 | 9.47 | 10.31 | 10.11 | 10.03 | 9.90 | 9.67 |
| 9 | 7.47 | 8.04 | 8.62 | 9.14 | 9.53 | 9.80 | 9.98 | 10.16 | 10.82 | 11.79 | 11.58 | 11.48 | 11.32 | 11.05 |
| 10 | ≈ 8.00 | 8.76 | 9.47 | 10.11 | 10.60 | 10.96 | 11.20 | 11.43 | 12.18 | 13.28 | 13.05 | 12.94 | 12.76 | 12.44 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 13.051 |
| SC2 | 0 | 8 | 8.895 |
| SC3 | -18 | 7 | 7.173 |
| SC4 | -25 | 6 | 5.816 |
| SC5 | -34 | 6 | 5.388 |
| A | 1467 mm |
|---|---|
| B | 586 mm |
| C | 605 mm |
| F | 395 mm |
| E1 | 568 mm |
| E | 1135 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø28 |
| Length | 1467 mm |
|---|---|
| Width | 586 mm |
| Height | 605 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.